Maintenance Object Repair Procedure
555-233-142
8-894 Issue 1 May 2002
1004 ABORT The port was seized by a valid call during the test. The test has been aborted.
1. Use the display port UUCSSpp command to determine the data module
extension. Then use status data module command with the extension
number to determine the service state of the data module. If the data
module is in use, wait until the port is idle before retesting.
2000 ABORT Response to the test request was not received within the allowable time period.
1. Retry the command at 1-minute intervals up to 5 times.
2100 ABORT System resources required for this test are not available.
1. Retry the command at 1-minute intervals up to 5 times.
2500 ABORT Internal system error
1. Retry the command at 1-minute intervals up to 5 times.
7 FAIL Conference test failed on the primary information channel. In some cases,
user may not notice disruption in service. In extreme cases, conferencing
feature may not work at all.
14 FAIL The primary information channel is not transmitting properly. User impact may
range from noticing nothing to not being able to use this port.
15 FAIL The control channel between the processor and Digital Line circuit pack is not
transmitting properly. This can cause a wide range of effects. The user may
notice nothing or the port may be totally unusable. This could also disrupt other
users.
1. Run circuit pack tests to check the Tone Generator and the Tone Detector
circuit packs using the test board UUCSS short command.
2. Resolve any problems that are detected on the Tone Generator circuit pack
or Tone Detector circuit pack.
3. If the Tone Generator and Tone Detector circuit packs are functioning
properly, and the test still fails, replace the Digital Line circuit pack.
16 FAIL The secondary information is not transmitting properly. This can cause a wide
range of effects. The user may notice nothing or the port may be totally
unusable.
1. To be sure that this is not an intermittent problem, repeat this test up to up
to 10 times to make sure it continues to pass.
2. If complaints still exist (poor data transmission), examine the data module,
connections, and wiring.
PASS Information and Control Channel Local Loop test passed. Every channel is
transmitting properly.
Table 8-379. Test #13 Information and Control Channel Local Loop Test Continued