Maintenance Object Repair Procedure
555-233-142
8-1012 Issue 1 May 2002
FAIL
(cont’d)
6. Since the test still fails, the ring generator is defective.
a. If the reset button on the ring generator is out, press it in.
b. Originate calls to several analog stations on different port circuit packs
in different carriers in the affected port network.
c. If called stations ring, the fault is cleared. Proceed to Step d. If no
stations ring, replace the ring generator.
d. Rerun the test. If the test still fails, proceed to Step 7.
7. The active Tone-Clock may be faulty and incorrectly reporting the level of
the ringing voltage. Replace the active Tone-Clock, and rerun the test.
See ‘‘TONE-BD (Tone-Clock Circuit Pack)’’ on page 8-1173 for details on
replacing the Tone-Clock. Rerun the test.
PASS The analog ringing voltage level is acceptable. For a single-carrier cabinet
stack, ringing voltage is acceptable in the cabinet containing the active
Tone-Clock circuit pack.
Table 8-431. Test #118 Analog Ring Generator Query Test — Continued
Error
Code
Tes t
Result Description / Recommendation
Continued on next page