Maintenance Object Repair Procedure
555-233-142
8-1014 Issue 1 May 2002
Figure 8-38. Fan Removal
Hardware Error Log Entries and Test to Clear
Val ues
Notes:
a. Error Type: 1 – The power-/fan-status lead indicates that an RMC
cabinet’s power supply has detected an alarm condition. The condition can
be caused by the failure of any fan’s or any power supply’s output. If more
than one RMC cabinet exists, every power-/fan-status lead is tied together.
Table 8-433. Cabinet sensors error log entries
Error
Type
Aux
Data Associated Test
Alarm
Level
On/Off
Board Test to Clear Value
0
1
1. Run the short test sequence first. If every test passes, run the long test sequence. Refer to the appropriate
test’s description, and follow the recommended procedures.
0 Any Any Any test environment
1(a) Any Cabinet Temperature or
Voltage Query test (#122)
MAJOR ON test environment