SYNC (Port-Network Synchronization)
Issue 1 May 2002
8-1035555-233-142
Figure 8-39. S8700 Media Server IP-Connected Sync Operation
The previous figure shows the third S8700 IP Connect systems PN without
public-network digital interface. A PN without public-network connectivity runs off
of its local IPSI circuit packs Tone-Clock circuit.
Clock Synchronization
This section discusses synchronization with Stratum-4 clocking devices.
Stratum-4 Synchronization
An EPN can be configured with primary and secondary synchronization
references (DS1 or UDS1 Interface circuit packs) when using Stratum-4
synchronization. A primary reference must be used as the synchronization
reference and a secondary reference is optional:
If the primary synchronization reference is not providing a valid timing
signal, the system automatically switches to the secondary synchronization
reference.
If the primary synchronization reference is invalid and secondary reference
does not provide a valid timing signal or is not administered as a
synchronization reference, an IPSIs Tone-Clock circuit provides the EPNs
timing source.
If the system (PN for S8700 Media Server systems) is using the local
oscillator as the timing source (both the primary and secondary references
are providing invalid timing signals), should either the primary or secondary
reference becomes valid again, the system (PN for S8700 Media Server
systems) switches back to the primary or secondary source.
PN PN PN
Public Switched Network
Primary
Primary
Secondary
Secondary
IP Network