Maintenance Object Repair Procedure
555-233-142
8-1038 Issue 1 May 2002
Troubleshooting Synchronization Problems
The following flow chart presents a logical approach to troubleshooting
synchronization problems in conjunction with the previous background
information. Explanatory notes follow the charts.
of 6
Figure 8-40. Synchronization Troubleshooting, Fig. 1 of 4
Slips
No
Yes
Is synchronization
enabled?
A
Is reference a
free-running IPSI
Synchronization is enabled
for this port network.
Fig 2
Slips on
DS1 facilities?
Problem is
in switch.
Fig 3
Fig 4
Problems with
reference PN or
synchronization plan
Slips on IPSIs Tone CLK circuit
or non-reference PN DS1s
C
B
1
1
2
Yes
No
Yes
No
Tone-Clock circuit?
Enable
synchronization.