Maintenance Object Repair Procedure
555-233-142
8-1124 Issue 1 May 2002
Error Log Entries and Test to Clear Values
Notes:
a. The IPSI circuit pack may have a clock at the edge of its specified
frequency.
1. Replace the IPSI circuit pack identified in the error log. See
‘‘Replacing the IPSI Circuit Pack’’ on page 8-1177.
b. This error type indicates that the circuit pack has been removed or has
been insane for more than 11 minutes. To clear the error, reinsert or
replace the circuit pack.
c. The tone-clock has reported an out-of-lock condition. A aux value of 1
indicates this error is an out-of-lock with the primary reference. A aux
value of 2 indicates this error is an out-of-lock with the secondary
reference. It could not lock onto the frequency of that synchronization
reference. This will lead to a change in the synchronization reference if the
condition continues.
Table 8-479. TDM Bus Clock Error Log Entries
Error
Type
Aux
Data Associated Test
Alarm
Level
On/Off
Board
1
1. As a general rule, any on-board errors against the TDM Bus Clock should be resolved before pursuing any other
errors against PNC components. Off-board clock errors may be caused by other board errors, and should
usually be addressed once any on-board errors have been resolved.
Te s t t o Cl ea r Val u e
0
2
2. Run the short test sequence first. If every test passes, run the long test sequence. Refer to each appropriate
tests description, and follow its recommended procedures.
0 Any Any Any test tone-clock UUC sh r 1
1 (a) 0 None MINOR OFF
130 (b) None
513 (c) Any Clock Circuit Status inquiry
(#148)
MINOR
3
3. Major or Minor alarms on this MO may have been downgraded to Warning alarms based on the values used in
the set options command.
OFF test tone-clock UUC
769 (d) Any Clock Circuit Status inquiry
(#148)
MAJOR
ON test tone-clock UUC sh r 10
1025 (e) Any Clock Slip inquiry(#149) test tone-clock UUC sh
1281,
1282 (f)
Any None MINOR OFF
1537 Any Clock PPM inquiry (#150) test tone-clock UUC sh
2305 (g) 0 None WARNING OFF

Table of Contents