TIE-DS1 (DS1 Tie Trunk)
Issue 1 May 2002
8-1141555-233-142
1004 ABORT The port was seized by a user for a valid call.
1. Use the display port UUCSSpp command to determine the trunk
group/member number of the port. Use the status trunk command to
determine the service state of the port. If the service state indicates that
the port is in use, then the port is unavailable for certain tests. You must
wait until the port is idle before retesting.
2. If the port status is idle, retry the command at 1-minute intervals up to 5
times.
1020 ABORT The test did not run because of a previously existing error on the specific port
or a more general circuit pack error.
1. Examine the Error Log for existing errors against this port or the circuit
pack and attempt to diagnose the already existing error.
2000 ABORT Response to the test request was not received within the allowable time period.
2100 ABORT System resources required for this test are not available.
1. Retry the command at 1-minute intervals up to 5 times.
2053 ABORT At least one of the following errors is found on the DS1 circuit pack:
1281 Loss of signal
1793 Blue alarm
2049 Red alarm
2305 Yellow alarm
1537 Hyperactivity
Look for the above error types in the Hardware Error Log and follow the
procedures given in the appropriate DS1-BD or UDS1-BD maintenance
documentation for the listed error types.
FAIL This can be due to either on- or off-board problems. Off-board problems of
concern include RMC-ENV faults, TDM-BUS faults, and faults associated with
the tone detectors/tone generators. Clear every off-board problem before
replacing the board. Keep in mind that a TDM-BUS problem is usually the
result of a faulty board connected to the backplane or bent pins on the
backplane.
1. Resolve any RMC-ENV errors.
2. Resolve any TDM-BUS errors.
3. Resolve any TONE-BD and/or TONE-PT errors.
4. Retest when the faults from steps 1, 2, and 3 are cleared. Replace the
board only if the test fails.
Table 8-486. Test #6 NPE Crosstalk Test Continued
Error
Code
Tes t
Result Description / Recommendation
Continued on next page