For TN439, Test #747 is run instead of #73. This test seizes a trunk and
outpulses a pause digit. This test aborts on ports administered as access
endpoints.
Table 8-496. Test #73,#747 Tie Trunk Seizure Test
Error
Code
Tes t
Result Description / Recommendation
ABORT Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals up to 5 times.
1000 ABORT System resources required to run this test are not available. The trunk may be
busy with a valid call. Use the display trunk xx to determine the trunk
group/member number of the port. Use the status trunk command to
determine the service state of the port. If the service state indicates that the
port is in use, then the port is unavailable for certain tests. You must wait until
the port is idle before retesting.
1. If the port status is active, but the port is idle (no calls), then check the
Error Log for Error Type 1025 (see Error Log table for description of this
error and required actions). The port may be locked up. The far-end PBX
may not be releasing.
2. If the port status is idle, then retry the command at 1-minute intervals up to
5 times.
1004 ABORT The port was seized by a valid call during the test. The test has been aborted.
Use the display trunk xx to determine the trunk group/member number of the
port. Use the status trunk command to determine the service state of the port.
If the service state indicates that the port is in use, then the port is unavailable
for certain tests. You must wait until the port is idle before retesting.
1. Retry the command at 1-minute intervals up to 5 times.
1005 ABORT This test is not valid for this trunk translation. Must be a wink-start or delay dial
trunk and must be outgoing or 2-way for this test to run. For the TN2140, the
trunk must also be continuous-seize-ack or discontinuous-seize-ack.
1. Check trunk translation. If it is not a wink-start or delay dial trunk, this abort
message should be ignored.
1018 ABORT Test disabled via administration.
1. Verify that the “Maintenance Tests?” field on the Trunk Group Form is set
to “n”. To enable the test, issue the change trunk-group x command
where “x” equals the number of the trunk group to be tested. Then change
the entry in the “Maintenance Tests?” field on the form to “y.”
1040 ABORT This test is not performed for trunk ports administered as access endpoints.
1. Verify this port is an access endpoint by using the display port command.
2. If the port has been administered as an access endpoint, then this test
should abort.
Continued on next page