Error Log Entries and Test to Clear Values
Table 8-501. Tone-Clock Circuit Pack Error Log Entries
Error
Type Aux Data Associated Test Alarm Level
On/Off
Board Test to Clear Value
0
1
1. Run the short test sequence first. If every test passes, run the long test sequence. Refer to each appropriate
tests description, and follow its recommended procedures.
0 Any Any Any test tone-clock PC sh
1 (a) 0 Circuit pack removed or
SAKI Sanity test (#53)
MINOR ON
23 (b) 0 None WARNING OFF
125 (c) None MINOR ON
126 (d) None MINOR ON
257 (e) 65535 Control Channel test
(#52)
MINOR ON test tone-clock PC r 20
257 (e) Any None
513 (f) Any None
769 (g) 4358 None
1025 (h) 4363 NPE Audit test (50) test tone-clock PC sh
1538 (i) Any None MINOR ON
2049 (j) 0 Clock Health Inquiry
test (#46)
MAJOR ON set tone-clock UC
override
3
2305 (j) 0 Clock Health Inquiry
test (#46)
MAJOR ON set tone-clock UC
override
3
2561 (k) Any None MAJOR ON
3329 (l) 0 None MINOR/
WARNING
2
2. Minor alarms on this MO may be downgraded to Warning alarms based on the value used in the set options
command.
3. Use the command set ipserver-interface.
OFF set tone-clock UC
override
3
3840 (m) Any None
3848 (n) 0 Clock Health Inquiry
test (#46)
set tone-clock UC
override
3
3856 (o) MAJOR ON set tone-clock UC
override
3
3857,
3858 (p)
NONE MAJOR ON busyout/release
ipserver-interface
3872 (q) 0 None set tone-clock UC
override
3
3999 (r) Any None

Table of Contents