Maintenance Object Repair Procedure
555-233-142
8-1188 Issue 1 May 2002
Error Log Entries and Test to Clear Values
Notes:
a. A failure in the tone generation facility on the indicated circuit pack has
been detected. Replace the circuit pack. See ‘‘Replacing the IPSI Circuit
Pack’’ on page 8-1177.
b. This error type indicates that the circuit pack has been removed or has
been insane for more than 11-minutes. To clear the error, reinsert or
replace the circuit pack.
c. The tone generation facility is having problems verifying that tones have
been connected as requested.
d. The tone generation facility may or may not be able to generate tones.
e. Infrequent errors, at a rate which does not bring up an alarm, probably do
not affect service, unless there are customer complaints of no tones, or
incorrect tones which can not be explained in any other way. However, if
an alarm is raised because this error is being repeatedly logged, then the
circuit pack should be replaced. See ‘‘Replacing the IPSI Circuit Pack’’ on
page 8-1177.
Table 8-505. Tone Generator Error Log Entries
Error
Type
Aux
Data Associated Test
Alarm
Level
On/Off
Board Test to Clear Value
0
1
1. Run the short test sequence first. If every test passes, run the long test sequence. Refer to each appropriate
tests description, and follow its recommended procedures.
0 Any Any Any test tone-clock UUC r 1
1 (a) 17664 Tone Generator Audit/
Update test (#41)
MAJOR ON test tone-clock UUC r 2
18 (b) 0 busyout tone-clock UUC WARNING OFF release tone-clock UUC
130 (b) None MINOR ON test tone-clock UUC Sh
257 (c, e) 17667 None MINOR ON
513 (d, e) 17666 Tone Generator Audit/
Update test (#41)
MINOR ON test tone-clock UUC r 3
769 Any Transmission test (#40) MAJOR ON test tone-clock UUC r 3
1025 Crosstalk test (#90) MAJOR ON test tone-clock UUC l r 2
1281 (f) Any Tone Generator Audit/
Update test (#41)
MINOR ON test tone-clock UUC r 3