Maintenance Object Repair Procedure
555-233-142
8-1226 Issue 1 May 2002
1312(p) Any Repeater Loopback
test (#1211)
WARNING
3
MINOR
OFF test ds1-loop UUCSS
ds1/csu-loopback-tests
1313(q) Any CPE Loop-Back Jack
test (#1212)
WARNING
3
MINOR
OFF test ds1-loop UUCSS
end-loopback/span-tes
t
1314(r) Any Far CSU Loopback
test (#1213)
WARNING
3
MINOR
OFF test ds1-loop UUCSS
end-loopback/span-tes
t
1320 Any Loss of Signal Alarm
Inquiry test (#138)
WARNING
3
MINOR
OFF test board UUCSS
1321 Any Loss of Signal Alarm
Inquiry test (#138)
WARNING
3
MINOR
OFF test board UUCSS
1322 Any Loss of Signal Alarm
Inquiry test (#138)
MINOR ON test board UUCSS
1323 Any Loss of Signal Alarm
Inquiry test (#138)
WARNING
3
MINOR
OFF test board UUCSS
1324 Any Loss of Signal Alarm
Inquiry test (#138)
WARNING OFF test board UUCSS
1400,
1401(s)
Any Loss of Signal Alarm
Inquiry test (#138) and
Echo Cancellation test
(#1420)
MINOR ON test board UUCSS
1537(t) 46082 WARNING
3
MINOR
ON
1538(u) Any WARNING
3
MINOR
ON
1793 Any Blue Alarm Inquiry test
(#139)
WARNING
MINOR
MAJOR
4
OFF test board UUCSS
1794 Any Blue Alarm Inquiry test
(#139)
WARNING
MINOR
MAJOR
4
OFF test board UUCSS
1795 Any Blue Alarm Inquiry test
(#139)
WARNING
MINOR
MAJOR
4
OFF test board UUCSS
2049 Any Red Alarm Inquiry test
(#140)
WARNING
3
MINOR
OFF test board UUCSS
Table 8-520. DS1 Interface Circuit Pack Maintenance Error Log Entries Continued
Error
Type
Aux
Data Associated Test Alarm Level
On/Off
Board Test to Clear Value
Continued on next page