UDS1-BD (UDS1 Interface Circuit Pack)
Issue 1 May 2002
8-1247555-233-142
1301 FAIL The 120A1 CSU module is not expected.
The 120A1 CSU module: The 120A1 CSU module is physically connected to
the UDS1 board behind the port carrier, but the Near-End CSU Type field
on the add ds1 form has not been administered as
integrated.
1. If the 120A1 CSU module is to be used, use the change ds1 command to
change the Near-End CSU Type field to integrated. Otherwise,
physically remove the 120A1 CSU module from the back of the port carrier.
2. Run the test again.
1302 FAIL Attempting to use the 120A1 CSU module with a UDS1 circuit pack that is
configured for 32-channel (2.048-Mbps) operation. The CSU module only
works with a DS1 board configured for 24-channel (1.544-Mbps) operation in
the United States of America.
1. If the 120A1 CSU module is to be used, physically remove the UDS1 circuit
pack and reconfigure for 24-channel (1.544-Mbps) operation.
2. Reinsert the circuit pack and run the test again.
1303 FAIL The DS1 circuit pack Suffix is incorrect for CSU module administration.
The DS1 circuit pack Suffix is incorrect for CSU module administration. The
Near-End CSU Type field on the add ds1 form has been administered as
integrated but the DS1 circuit pack is not a TN464F or later suffix UDS1
board.
1. If the CSU module is to be used, and the Near-End CSU Type field is
set to
integrated to allow for CSU module administration, remove the
circuit pack and replace it with a TN464F or later suffix board. Otherwise,
use the change ds1 command to change the
Near-End CSU Type
field to
other.
1310 FAIL The DS1 Board Loopback (BLB) demand test (#1209) failed.
1. Repeat the test using the test ds1-loop UUCSS ds1/csu-loopback-tests
command.
2. If the BLB test continues to fail, then replace the UDS1-BD circuit pack.
3. Run this test again.