Maintenance Object Repair Procedure
555-233-142
8-1250 Issue 1 May 2002
1324 FAIL A non-service-affecting CSU module audit failure was detected by the UDS1
circuit pack. No ports should be affected. No immediate action is required.
These errors indicate that the CSU module hardware may have a problem, and
that it should be replaced when practical to avoid further deterioration.
1400 FAIL Echo Canceller function failed. This could be a hardware problem on the
TN464GP/TN2464BP:
1. Issue the busyout board command.
2. Issue the reset board command.
3. Issue the test board long command.
4. Issue the release board command.
5. If Test 1420 still fails, replace the TN464GP/TN2464BP.
1401 FAIL Echo Canceller memory failed, this could be a hardware problem on the
TN464GP/TN2464BP:
1. Issue the busyout board command.
2. Issue the reset board command.
3. Issue the test board long command.
4. Issue the release busy board command.
5. If the test still fails, replace the TN464GP/TN2464BP.
PASS DS1 signal is present and the physical link is healthy. In addition, no Integrated
CSU errors or echo cancellation errors are detected.
0NO
BOARD
The test could not relate the internal ID to the port (no board). This could be
due to incorrect translations, no board is inserted, an incorrect board is
inserted, or an insane board is inserted.
1. Verify that the boards translations are correct. Execute the add ds1
UUCSS command to administer the UDS1 interface if it is not already
administered.
2. If the board was already administered correctly, check the error log to
determine whether the board is hyperactive. If so, the board is shut down.
Reseating the board will re-initialize it.
3. If the board was found to be correctly inserted in step 1, then issue the
busyout board command.
4. Issue the reset board command.
5. Issue the release busy board command.
6. Issue the test board long command.
This should re-establish the linkage between the internal ID and the port.
Table 8-526. Test #138 Loss of Signal Alarm Inquiry Test Continued
Error
Code
Tes t
Result Description / Recommendation
Continued on next page