Maintenance Object Repair Procedure
555-233-142
8-1378 Issue 1 May 2002
Error Log Entries and Test to Clear Values
Table 8-574. Common Port Circuit Pack Maintenance Error Log Entries
Error
Type
Aux
Data Associated Test
Alarm
Level
On/Off
Board Test to Clear Value
0
1
1. Run the short test sequence first. If every test passes, run the long test sequence. Refer to each appropriate
test’s description, and follow its recommended procedures.
0 Any Any Any test board UUCSS sh r 1
1 (a) 0 Circuit pack removed or
SAKI Sanity test (#53)
MINOR ON
18 (b) 0 busyout board UUCSS WARNING OFF release board UUCSS
23(c) 0 None WARNING OFF
36 (d) 4368 none
125 (e) None MINOR ON
217 (f) 0 None WARNING ON
257 65535 Control Channel test
(#52)
MINOR ON test board UUCSS sh r
20
267 (f) 0 None WARNING ON
513 (h) Any None MINOR ON test board UUCSS sh
769 (i) 4358 None
1025 (j) 4363 NPE Audit test (#50) test board UUCSS l r 20
1281 (k) Ringing Application test
(#51)
MINOR ON test board UUCSS r 2
1538 (l) Any None WARNING
MINOR
ON
1793 (m) Neon test (#220) MINOR ON test board UUCSS r 2
3840 (n) Any None
3999 (o) Any None