MIS (Management Information System)
Issue 1 May 2002
8-783555-233-142
MIS (Management Information
System)
The Management Information System (MIS)/Call Management System (CMS) MO
is used only to monitor MIS busyouts during administration of MIS translations.
There are no hardware failures associated with this MO.
The MIS/CMS is an adjunct processor that collects Automatic Call Distribution
(ACD) data sent from the switch. In order to change MIS translations, a switch
administrator must first enter a busyout mis command at the G3-MT. When the
MIS is busied out, the switch will stop sending ACD data to the MIS, and a
Warning alarm will be raised.
When the switch administrator is finished, a release mis command should be
entered at the terminal. This will clear the Warning alarm and allow the switch to
send ACD data to the MIS.
Error Log Entries and Test to Clear Values
MOs Name
(in Alarm Log)
Alarm
Level Initial Command to Run Full Name of MO
MIS WARNING release mis Management Information System
Table 8-336. Management Information System Error Log Entries
Error
Type
Aux
Data Associated Test Alarm Level
On/Off
Board
Test to Clear
Va lue
0
1
1. Run the short test sequence first. If every test passes, run the long test sequence. Refer to each
appropriate tests description, and follow its recommended procedures.
0 Any Any Any release mis
18
2
2. When the busyout MIS command is issued, no data is sent to the MIS/CMS regardless of the link state.
To allow data to be sent to MIS/CMS, a release mis command must be issued from the terminal.