XR Series Installation and Technical Instructions 15
Remove the Electronics
Carriage
1. Once the electronics carriage has been lowered from the main
enclosure, disconnect the AC power and ground connections from the
power supply board.
2. Disconnect the green ground wire from the electronics carriage
frame.
3. Angle the electronics carriage so the tabs are at opposite corners of
the main enclosure opening.
4. Guide the electronics carriage free of the main enclosure.