Specifications: Power
Stage 16
Power
Stage 16 measurements taken using 0dBFS level on all analog output channels.
Phantom power load of 4mA placed on 13 of 16 input channels.
Parameter Measurement Units Accuracy (±) Notes
RMS Input Voltage 110 VAC 0.05% + 0.25V
Frequency 60 Hz 0.1% ± 1 digit
RMS Input Current 0.37 A 0.1% + 0.15A
Peak Input Current 50.0 A 0.2% + 0.5A Internally limited by AC supply
VA (Reactive) Power 44.0 VA 0.15% + 9 VA
Real Power 43 W 0.15% + 9 W
Power Factor 0.96 0.03
Stage 16 I/O Rack Power Measurements, 110V/60Hz