- 30 -
Management of SMS on the way out
The control panel has the possibility of sending specic messages according to the events generated..
These messages can be both technical or alarm messages and/or of inputs restore.
Technical Messages: they are related to situations such as supplying anomalies, as battery and
are automatically dialled making use of a library of per-recorded messages.
Zone messages: are related to signalling of zone inputs for both alarm communication, restore and
exclusion.
The zone SMS are dialled by the sequence of 4 standard words to which a zone strip can be
added.
Management of incoming SMS
It is possible to ask the control panel the execution of commands from remote way, using sms
appropriately codied.
The same operations as for the vocal RTC connection can be required.
The incoming sms are executed only if:
• the calling telephone number is associated to a user
• the associated user is enabled to RTC with automatic validation according to telephone
number
• their syntax is correct
• require actions to which the user is enabled
More commands can be put in the end of the same message, provided that:
• the total length is not over 46 characters
• the commands are separated by #
• any command is preceded and followed by #
List of the Commands
Type Syntax Example
oc activation #act number_oc# #act 13#
oc deactivation #deact number_oc# #deact 13#
control panel arming #act [on|ho|zo|pe] sector# #arm ho 2#
control panel disarming #sp sector# #sp 2#
zone exclusion #excl number_zone# #excl 12#
zone inclusion #incl number_zone# #incl 12#
sector state request #state sector N# #state sector 2#
sectors state request #sectors state# #sectors state#
zone state request Referred to:
Open/Tamper/Excluded/Supervision
#state zone N# #state zone 2#
zones state request #zones state# #zones state#
output state request #state output N# #state output 5#
outputs state request #outputs state# #outputs state#
system state request
Referred to: technical anomalies
#system state# #system state#
conrm operations #res# #res#
calls block #stop# #stop#
- Example of CORRECT sequences: #excl 12#excl 15#arm on 2#zones state#
Nota: The exceeding space will be removed