Appendix B: The Parameter List
56 AXIS 700 User’s Manual
[SNMP]
GetCommunityName = public
Specifies the community that has read only access to all
supported SNMP objects except WriteCommunity,
SupervisorPassword and ftpPassword. It corresponds to the
ReadCommunity SNMP object.
SetCommunityName = pass
Specifies the community that has read-write access to all
supported SNMP objects except read only objects. It
corresponds to the WriteCommunity SNMP object.
TrapDestination = 0.0.0.0
Specifies the Internet Address which SNMP traps are sent to. It
corresponds to the TrapAddress SNMP object. Default is 0.0.0.0,
i.e. all SNMP traps are disabled.
TrapCommunityName = public
Specifies the community for all generated SNMP traps. It
corresponds to the TrapCommunity SNMP object.
SystemContact =
Optional entry which should be in plain text and may be used to
show the name of the system contact person.
SystemName =
Optional entry which should be in plain text and may be used to
show the name of the location of the system.
SystemLocation =
Optional entry which should be in plain text and may be used to
show the name of the location of the system.
AuthenticationTrap = disabled
Enables or disables the SNMP authentication failure traps. It
corresponds to the snmpenableAuthenTraps (MIB-II) SNMP
object.
[Clients]
InformationLevel = Nothing
The information to be transmitted with the image. Possible
values are
Nothing, Profile
or
AllSettings.
FTPDefaultUser = anonymous
If not set for a destination, this default user will be used.
FTPDefaultPassword = AXIS_700@any.com
If not set for a destination, this password will be used. This field
can also contain the identity of the user transmitting the scanned
image. This is useful for administrative purposes.
FTPDefaultPrefix = pic
If no prefix has been assigned to the transmitted file, this prefix
will be used.
SMTPMailServer =
Name of the server that provides your e-mail facilities.
SMTPReplyAddress = AXIS_700@any.com
The e-mail address of the person responsible for the
administration of the AXIS 700.
SMTPSubject = An image scanned
with AXIS 700
Text that will be placed on the Subject line of the e-mail text
body.
[END]