AXISA1001NetworkDoorController
EnduranceIV
StandbyPower
I
WireArea
NO NO
NO
TICE TICE
TICE
Eachwireshallhaveanconductorcross-sectionalareathatcorrespondstoanconductor
gaugerangeofAWG28–16(CSA)orAWG22–14(cUL/UL).Selectcablesincompliance
withyourlocalregulations.
AWG
Diametermm(in)
Areamm
2
28–16
0.321–1.29(0.0126–0.0508)
0.0810–1.31
22–14
0.644–1.63(0.0253–0.0641)
0.326–2.08
Connectors
Forinformationabouttheconnectors’positions,seeHardwareoverviewonpage14.
Forconnectiondiagramsandinformationaboutthehardwarepinchartgeneratedthroughthe
hardwareconguration,seeConnectionDiagramsonpage28andConguretheHardwareon
page41.
Thefollowingsectiondescribestheconnectors’technicalspecications.
ReaderDataConnector
6-pinterminalblocksupportingRS485andWiegandprotocolsfor
communicationwiththereader.
TheRS485portssupport:
•Two-wireRS485halfduplex
•Four-wireRS485fullduplex
TheWiegandportssupport:
•Two-wireWiegand
22