7EtherNet/IP Connection Procedure
27
3
After entering, right-click under
the entered variable, and
select Create New from the
menu.
A new variable can be entered.
Enter EIP002_IOLink_port0_1
_OUT in the Name Column.
Enter BYTE[64] in the Data
Type Column.
After entering, check that the
data type changes to
ARRAY[0..63] OF BYTE.
Select Output from the
pull-down list of Network
Publish.
4
In the same way as step 3,
enter the following data in the
newly added rows.
Name:
EIP002_IOLink_port2_3_
OUT
Data Type: BYTE[64]
Network Publish: Output
Name:
EIP002_IOLink_port4_5_
OUT
Data Type: BYTE[64]
Network Publish: Output
Name:
EIP002_IOLink_port6_7_
OUT
Data Type: BYTE[64]
Network Publish: Output