Defined Area
Models
Response
Time # BeamsEmitter Receiver Pair
3
410 mm
SLPE25-410P8 SLPMR25-410P12 SLPMP25-410P128
9.5 ms 21
SLPE25-410 SLPMR25-410 SLPMP25-410
550 mm
SLPE25-550P8 SLPMR25-550P12 SLPMP25-550P128
11 ms 28
SLPE25-550 SLPMR25-550 SLPMP25-550
690 mm
SLPE25-690P8 SLPMR25-690P12 SLPMP25-690P128
12.5 ms 35
SLPE25-690 SLPMR25-690 SLPMP25-690
830 mm
SLPE25-830P8 SLPMR25-830P12 SLPMP25-830P128
14 ms 42
SLPE25-830 SLPMR25-830 SLPMP25-830
970 mm
SLPE25-970P8 SLPMR25-970P12 SLPMP25-970P128
15.5 ms 49
SLPE25-970 SLPMR25-970 SLPMP25-970
1110 mm
SLPE25-1110P8 SLPMR25-1110P12 SLPMP25-1110P128
17 ms 56
SLPE25-1110 SLPMR25-1110 SLPMP25-1110
1250 mm
SLPE25-1250P8 SLPMR25-1250P12 SLPMP25-1250P128
18.5 ms 63
SLPE25-1250 SLPMR25-1250 SLPMP25-1250
1390 mm *
SLPE25-1390P8 SLPMR25-1390P12 SLPMP25-1390P128
20 ms 70
SLPE25-1390 SLPMR25-1390 SLPMP25-1390
1530 mm *
SLPE25-1530P8 SLPMR25-1530P12 SLPMP25-1530P128
21 ms 77
SLPE25-1530 SLPMR25-1530 SLPMP25-1530
1670 mm *
SLPE25-1670P8 SLPMR25-1670P12 SLPMP25-1670P128
22.5 ms 84
SLPE25-1670 SLPMR25-1670 SLPMP25-1670
1810 mm *
SLPE25-1810P8 SLPMR25-1810P12 SLPMP25-1810P128
24 ms 91
SLPE25-1810 SLPMR25-1810 SLPMP25-1810
* Lengths longer than 1250 mm are no longer available.
3.6 Operating Features
The EZ-SCREEN Low-Profile System with Integral Muting models feature these standard functions.
Integrated Muting—
Muting Functions
(p. 53)
Reduced Resolution (Floating Blanking)—
Reduced
Resolution (Floating Blanking)
(p. 39)
Trip or Latch Output—
Selectable Trip/Latch
Outputs
(p. 68)
External Device Monitoring (EDM)—
External Device
Monitoring
(p. 45)
Auxiliary Output; OSSD Follow or Fault—
Auxiliary
(OSSD Follow/Fault) Output
(p. 45)
Scan Code setting—
Scan Code Configuration
(p.
69)
Fixed Blanking—
Fixed Blanking
(p. 40)
Emitter Test and Fault functions
Inverted Display—
Inverted Display
(p. 69)
Eight different standard muting configuration options
Mute Lamp Monitoring—
Mute Lamp Output
(p.
63)
Override and Bypass—
Bypass and Mute-
Dependent Override
(p. 65)
Mute Enable—
Mute Enable (ME)
(p. 61)
These functions are configured via DIP switches (behind the access door on the front of each sensor) and/or the sensor
wiring
configuration. The sensing resolution is determined by the emitter and receiver model.
3
A pair includes an emitter and a receiver
EZ-SCREEN Low-Profile System with Integral Muting
www.bannerengineering.com - Tel: + 1 888 373 6767 13

Table of Contents