13.3 Contactors
The normally closed contacts are used in an external device monitoring (EDM) circuit. If used, two contactors per EZ-
SCREEN LPM System are required. See datasheet p/n
111881
for additional options and more information.
Model Description
11-BG00-31-D-024 10 amp positive-guided contactor, 3 N.O., 1 N.C.
BF1801L024 18 amp positive-guided contactor, 3 N.O., 1 N.C. (N.C. contact rated at 10 amps)
13.4 External Keyed Reset Switches
Model Description
EZA-RR-1
External normally open reset switch with 8-pin M12/Euro-style QD; can be interconnected using cordset models QDE-8..D,
DEE2R-8..D, or CSB-..M1281.
MGA-KSO-1 Panel-mount keyed normally open reset switch
MGA-K-1 Replacement key for switch MGA-KSO-1
13.5 Snap-On Lens Shields
Impact-resistant copolyester lens shields snap easily over entire length of sensor housing, protecting against metal cutting
fluids
and other chemicals. The lens shields are not sealed at the top and bottom, and decrease sensing range by
approximately 15% when they are protecting both the emitter and receiver. Order one per sensor.
Sensor Model Lens Shield Model
SLP..-410.. LPSS-410
SLP..-550.. LPSS-550
SLP..-690.. LPSS-690
SLP..-830.. LPSS-830
SLP..-970.. LPSS-970
SLP..-1110.. LPSS-1110
SLP..-1250.. LPSS-1250
EZ-SCREEN Low-Profile System with Integral Muting