Callout Description
F QS18VP6LPQ8 (4-pin Euro) sensors shown in figure. Other sensors or switches may be used.
13.1.6 4 and 5-Pin M12/Euro QD Cordsets
Table 12: 4-Pin Cordsets
Model Length Banner Cordset Pinout/Color Code M12/Euro Connector (female face view)
DELPEF-40D 0.05 m (2.4 in)
QD pin Function
1 N.C.
2 N.C.
3 0 V dc
4 Mute Status
DELPEF-41D 0.3 m (1 in)
DELPEF-43D 1 m (3.3 in)
DELPEF-48D 2.5 m (8 in)
DELPEF-415D 4.5 m (15 ft)
DELPEF-425D 7.6 m (25 ft)
DELPEF-450D 15.2 m (50 ft)
DELPEF-475D 22.8 m (75 ft)
DELPEF-4100D 30.4 m (100 ft)
Table 13: 5-Pin Cordsets
Model Length Banner Cordset Pinout/Color Code M12/Euro Connector (female face view)
DELPEF-50D 0.05 m (2.4 in)
QD pin Function
1 Reset Status
2 OSSDs Off
3 0 V dc
4 OSSDs On
5 Mute Status
DELPEF-51D 0.3 m (1 in)
DELPEF-53D 1 m (3.3 in)
DELPEF-58D 2.5 m (8 in)
DELPEF-515D 4.5 m (15 ft)
DELPEF-525D 7.6 m (25 ft)
DELPEF-550D 15.2 m (50 ft)
DELPEF-575D 22.8 m (75 ft)
DELPEF-5100D 30.4 m (100 ft)
13.2 Interface Modules
IM-T-..A interface modules provide forced-guided, mechanically-linked relay (safety) outputs for the EZ-SCREEN LPM
System See the Banner datasheet for more information.
Model Description Datasheet
IM-T-9A
Interface module, 3 normally open (N.O.) redundant-output 6 amp contacts, removable screw
terminals
62822
IM-T-11A
Interface module, 2 normally open (N.O.) redundant-output 6 amp contacts, plus 1 normally closed
(N.C.) auxiliary contact, removable screw terminals
SR-IM-9A Interface module, 3 normally open (N.O.) redundant-output 6 amp contacts, spring clamp terminals
208873
SR-IM-11A
Interface module, 2 normally open (N.O.) redundant-output 6 amp contacts, plus 1 normally closed
(N.C.) auxiliary contact, spring clamp terminals
EZ-SCREEN Low-Profile System with Integral Muting
88 www.bannerengineering.com - Tel: + 1 888 373 6767