5.3.2 Sensor Mounting and Mechanical Alignment
Verify that:
The emitter and receiver are directly opposite
each other
Nothing is interrupting the defined area
The
defined area is the same distance from a
common reference plane for each sensor
The emitter and receiver are in the same plane
and are level/plumb and square to each other
(vertical, horizontal, or inclined at the same
angle, and not tilted front-to-back or side-to-
side)
Figure 17. Incorrect Sensor Alignment
Level Surface
X X
Emitter Receiver
level
level
Y Y
Z
Z
Level Surface
A B
level level
XX
Angled or Horizontal Installations – verify that:
Distance X at the emitter and receiver are equal
Distance Y at the emitter and receiver are equal
Distance Z at the emitter and receiver are equal from
parallel surfaces
Vertical face (the window) is level/plumb
Defined
area is square. Check diagonal
measurements if possible; see Vertical Installations,
on the right.
Vertical Installations – verify that:
Distance X at the emitter and receiver are equal
Both sensors are level/plumb (check both the side
and face)
Defined area is square. Check diagonal
measurements if possible (Diagonal A = Diagonal B).