Figure 15. End-mount hardware attachment
No bracket
mounting here
No bracket
mounting here
Mount brackets
within this area
Bracket
Clamp
Note proper orientation
M3 x 10
Torque to 9 in-lbs (1.0 N-m)
M3 x 6
T
orque to
9 in-lbs (1.0 N-m)
Side brackets must be used
with longer sensors, if they are
subject to shock or vibration. In
such situations, the sensors
are designed to be mounted
with up to 690 mm unsupported
distance (between brackets).
Sensors 830 mm and longer are
supplied with one or more
additional side brackets for
center-mounting.
Ensure that clamp assembly is
fully seated onto “dovetail”
feature on side of housing
Figure 16. Side-mount hardware attachment