EasyManua.ls Logo

Banner EZ-SCREEN LPM Series - Emitter and Receiver Resets

Banner EZ-SCREEN LPM Series
104 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
12.3 Emitter and Receiver Resets
WARNING:
Lockouts and power failures indicate a problem
Attempts to continue to operate machinery by bypassing the Banner device or other safeguards
is dangerous and could result in serious injury or death.
A Qualified Person
17
must immediately investigate the problem.
WARNING:
Shut down the machinery before servicing
Servicing the Banner device or system while the hazardous machinery is operational could result
in serious injury or death.
The machinery to which the Banner device or system is connected must not be operating at any
time during major service or maintenance. This might require lockout/tagout procedures (refer to
OSHA1910.147, ANSI Z244-1, ISO 14118 or the applicable standard for controlling hazardous
energy).
The EZ-SCREEN LPM receiver and emitter each have a Reset input that provides for a manual reset input signal.
The receiver requires a manual reset to clear a Latch condition and resume operation following a stop command. Internal
Lockout conditions also require a manual reset to return either the emitter or the receiver to Run mode after the failure has
been corrected. Emitter resets are needed only in the unlikely event that a Lockout occurs.
Receiver manual resets are required in the following situations:
Trip Output operation – only after a Lockout (see
Lockout Conditions
(p. 76) for causes).
Latch Output operation – at power-up, after each Latch condition occurs, or after a Lockout.
Reset Routine
To reset the emitter and/or receiver:
1. Close the reset switch for 0.25 to 2 seconds.
2. Open the reset switch.
An alternative method to reset either component is to power the sensor down, then power it up.
If reset switch model MGA-KSO-1 (see
Accessories
(p. 82) ) is used:
1. Turn the key 1/4 turn clockwise to close.
2. Turn the key counterclockwise, back to its original position, to open.
Note: Closing the reset switch too long will cause the sensor to ignore the reset request; the switch must
be closed from 0.25 seconds to 2 seconds, but no longer.
Note: If the receiver is set for latch output, a manual reset using a remote switch, as described in , is
required to resume full operation.
17
A person who, by possession of a recognized degree or certificate of professional training, or who, by extensive knowledge, training and
experience, has successfully demonstrated the ability to solve problems relating to the subject matter and work.
EZ-SCREEN Low-Profile System with Integral Muting
www.bannerengineering.com - Tel: + 1 888 373 6767 77