EasyManua.ls Logo

Banner EZ-SCREEN LPM Series - Selectable Trip;Latch Outputs

Banner EZ-SCREEN LPM Series
104 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Light Screen
Defined Area
M1
M2
Reset/OR1
ME/OR2
Override
OSSD
Outputs
< 3s
Don’t care
< 3s
Blocked
Clear
Off
On
Active
Inactive
Open
Closed
Open
Closed
Open
Open
Override ends due to
defined area
is clear
No override due to M1 &
M2 both open
Figure 41. Timing logic: Mute configuration 7, Mute-Dependent Override Function
EZ-SCREEN Low-Profile System with Integral Muting
www.bannerengineering.com - Tel: + 1 888 373 6767 67

Table of Contents