Beam Spot Size
x
y
Beam
Spot
Pattern
BeamspotsizesaremeasuredX×Ymmatspecificdis
tances.
2000 mm Models:
2.6×1.5mmat100mm
4.2×2.5mmat1000mm
6×3.6mmat2000mm
3000 mm Models:
2.6×1.5mmat100mm
4.2×2.5mmat1000mm
6×3.6mmat2000mm
7.8×4.7mmat3000mm
5000 mm Models:
6×4mmat100mm
11×7mmat2500mm
15×11mmat5000mm
10000 mm Models:
7×6mmat100mm
16×11mmat2500mm
25×19mmat5000mm
32×25mmat7500mm
41×31mmat10000mm
Beamspotsizeiscalculatedas1.6timestheD4σmeasured
value
Certifications
Certifications
Banner Engineering BV
Park Lane, Culliganlaan 2F bus 3
1831 Diegem, BELGIUM
Class2power;ULEnvironmentalRating:Type
1
VCCI-CISPR 32
Required Overcurrent Protection
WARNING: Electrical connections must
bemadebyqualifiedpersonnelinac
cordancewithlocalandnationalelectri
calcodesandregulations.
Overcurrentprotectionisrequiredtobeprovidedbyendprod
uctapplicationperthesuppliedtable.
Overcurrent protection may be provided with external fusing
or via Current Limiting, Class 2 Power Supply.
Supply wiring leads < 24 AWG shall not be spliced.
For additional product support, go
towww.bannerengineering.com.
Supply
Wiring
(AWG)
Required Overcurrent
Protection (A)
Supply
Wiring
(AWG)
Required Overcurrent
Protection (A)
20 5.0 26 1.0
22 3.0 28 0.8
24 1.0 30 0.5
FCC Part 15 Class A
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These
limitsaredesignedtoprovidereasonableprotectionagainstharmfulinterferencewhentheequipmentisoperatedinacommercialenviron
ment.Thisequipmentgenerates,uses,andcanradiateradiofrequencyenergyand,ifnotinstalledandusedinaccordancewiththeinstruc
tion manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause
harmfulinterferenceinwhichcasetheuserwillberequiredtocorrecttheinterferenceathisownexpense.
Industry Canada ICES-003(A)
This device complies with CAN ICES-3 (A)/NMB-3(A). Operation is subject to the following two conditions: 1) This device may not cause
harmfulinterference;and2)Thisdevicemustacceptanyinterferencereceived,includinginterferencethatmaycauseundesiredoperation.
Cet appareil est conforme à la norme NMB-3(A). Le fonctionnement est soumis aux deux conditions suivantes : (1) ce dispositif ne peut pas