Q5X with Dual Discrete Outputs and IO-Link Quick Start Guide
July 25, 2023 page13
Beam Spot Size
BeamspotsizesaremeasuredX×Ymmatspecificdis
tances.
2000 mm Models:
2.6×1.5mmat100mm
4.2×2.5mmat1000mm
6×3.6mmat2000mm
3000 mm Models:
2.6×1.5mmat100mm
4.2×2.5mmat1000mm
6×3.6mmat2000mm
7.8×4.7mmat3000mm
5000 mm Models:
6×4mmat100mm
11×7mmat2500mm
15×11mmat5000mm
10000 mm Models:
7×6mmat100mm
16×11mmat2500mm
25×19mmat5000mm
32×25mmat7500mm
41×31mmat10000mm
Beamspotsizeiscalculatedas1.6timestheD4σmeasured
value
Certifications
Certifications
Banner Engineering BV
Park Lane, Culliganlaan 2F bus 3
1831 Diegem, BELGIUM
Class2power;ULEnvironmentalRating:Type
1
VCCI-CISPR 32
Required Overcurrent Protection
WARNING: Electrical connections must
bemadebyqualifiedpersonnelinac
cordancewithlocalandnationalelectri
calcodesandregulations.
Overcurrentprotectionisrequiredtobeprovidedbyendprod
uctapplicationperthesuppliedtable.
Overcurrent protection may be provided with external fusing
or via Current Limiting, Class 2 Power Supply.
Supply wiring leads < 24 AWG shall not be spliced.
For additional product support, go
towww.bannerengineering.com.
Supply
Wiring
(AWG)
Required Overcurrent
Protection (A)
Supply
Wiring
(AWG)
Required Overcurrent
Protection (A)
20 5.0 26 1.0
22 3.0 28 0.8
24 1.0 30 0.5
FCC Part 15 Class A
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These
limitsaredesignedtoprovidereasonableprotectionagainstharmfulinterferencewhentheequipmentisoperatedinacommercialenviron
ment.Thisequipmentgenerates,uses,andcanradiateradiofrequencyenergyand,ifnotinstalledandusedinaccordancewiththeinstruc
tion manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause
harmfulinterferenceinwhichcasetheuserwillberequiredtocorrecttheinterferenceathisownexpense.
Industry Canada ICES-003(A)
This device complies with CAN ICES-3 (A)/NMB-3(A). Operation is subject to the following two conditions: 1) This device may not cause
harmfulinterference;and2)Thisdevicemustacceptanyinterferencereceived,includinginterferencethatmaycauseundesiredoperation.
Cet appareil est conforme à la norme NMB-3(A). Le fonctionnement est soumis aux deux conditions suivantes : (1) ce dispositif ne peut pas
occasionner d'interférences, et (2) il doit tolérer toute interférence, y compris celles susceptibles de provoquer un fonctionnement non
souhaité du dispositif.
© Banner Engineering Corp.