M1
M2
M2
M1
D
A
B
D
Figure 43. Muting function in the T configuration
Use the L configuration when the SX5 is mounted vertically and Unidirectional is selected in the configuration. This
configuration is suitable for applications requiring unidirectional movement of objects. This configuration uses two mute
sensors (e.g. two pairs of opposed-mode photoelectric sensors) stationed on one side of the Safety Zone. The muting is
initiated when the two sensors are made within the configured time of each other in the proper order (mute 1, then mute 2).
The mute cycle ends when the configured time limit is reached after the first mute sensor clears.
M1
M2
D
A
Figure 44. Muting function in the L configuration
CAUTION: Unidirectional muting should only be used for removing materials from the dangerous area.