Icon Fault Code Device Status OSSD Status Description
INPUTCF2 Lockout Off Check the input sequence.
OSSDF1 Lockout Off
Check the OSSD connections or the integrity of the external switching
device. If the failure persists, contact the factory for support.
OSSD1F3 Lockout Off
A short circuit to ground (GND) has been detected. Check the OSSD
connections or the integrity of the external switching device. If the
failure persists, contact the factory for support.
INTF1-20 Lockout Off
Internal Failure.
Reset the system using the reset function or cycle power to the device.
If the failure persists, contact the factory for support.
9.5 Safety
WARNING:
• If the device is not working properly, personnel may not be detected.
•
Failure to follow these instructions could result in serious injury or death.
• Stop the machine operation if the machine behaves unpredictably or if the behavior cannot be
identified.
• Stop the machine operation if you cannot identify or locate the fault or you cannot correct the
fault.
•
Secure the machine so that it cannot be unintentionally turned on.
WARNING:
• Do not start up the machine unexpectedly.
•
Failure to follow these instructions could result in serious injury or death.
• When any work is taking place, use the protective device to secure the machine or to ensure that
the machine is not switched on unintentionally.
WARNING:
• If the device is not working properly, personnel may not be detected.
•
Failure to follow these instructions could result in serious injury or death.
• Do not attempt to repair the device components.
• Do not make any changes to or tamper with the device components.
• With the exception of the procedures described in this document, the device components must
not be opened.
Important: If you cannot remedy the fault with the help of the information provided in this chapter, please
contact the factory.
SX5 Safety Laser Scanner
www.bannerengineering.com - Tel: +1.763.544.3164 85