Icon Fault Code Device Status OSSD Status Description
MUT
TIMEOUT
Normal On
Muting has expired because it is maintained beyond the maximum
timeout time.
MUTING
ERR
Normal On
Muting has not activated because the correct sequence was not
followed.
MUTING Normal On The Muting function is active.
OVERRIDE
ERR
Normal On
Override has not been activated because the correct sequence has not
been followed or there are no override conditions.
OVERRIDE Normal On The Override function is active.
OVERTEMP Normal On
The unit is operating above or below its allowed operating temperature
range.
OVR
TIMEOUT
Normal On The Override timeout function has expired.
CLEANW1 Normal Off
Clean the window until the normal condition is restored.
If cleaning the window does not restore the device to a normal
condition, replace the damaged scanner. Contact the factory for
support.
INPUTCF1 Lockout Off Check the input connection or sequence.