85R5911438 /09 UDM
7.4 Use case 4: Loop-through mode
Loop-through mode
Image 7–4
1 SFP input board
2 Neutrik OpticalCon Duo
3 Neutrik OpticalCon Quad
4 Internal fiber cable
5 SFP+ fiber transceiver
6 Advanced Quad cable
Barco delivers only the SFP input and SFP+ fiber transceivers. The customer has to buy the SFP+
transceiver and the optional breakout adapter or the fiber integrated cable.
How to configure the SFP input
1. Remove both plates covering the access to a Neutrik connector locations.
2. Mount the Neutrik OpticalCon Quad connector and the Neutrik OpticalCon Duo.
3. Remove the plate covering the access to the SFP cage and insert the SFP+ transceivers.
4. Re-install the cover plate.
5. Mount the fiber internal cables between the Neutrik OpticalCon Quad and the SFP+ transceivers.
6. Mount the fiber internal cables between the Neutrik OpticalCon Quad and the Neutrik OpticalCon Duo.
7. Install the SFP input in its slot of the Input & Communication module. See procedure “Installation of an
input board”, page 55.
Pulse SFP input use cases