24-2 9492600990
Testing DECS-150
Graph Parameters
Any four of the following parameters may be selected for plotting in the graph areas.
APC Error to PI
APC Integrator state
APC PI output
Auxiliary voltage input (Vaux)
Average line current (Iavg)
Average line-to-line voltage (Vavg)
AVR error signal (Errln)
AVR output
Bus frequency (B Hz)
Bus voltage (Vbus)
Compensated frequency deviation (CompF)
Control output (CntOp)
Cross-current input (Iaux)
Desired APC Reference
Droop
FCR error
FCR state
FCR output
Field current (Ifd)
Field voltage (Vfd)
Filtered mechanical power (MechP)
Final PSS output (Pout)
Frequency response signal (Test)
Generator/Motor frequency (G/M Hz)
Grid connect state
Grid code test signal
Internal state (TrnOp)
Lead-lag #1 (x15)
Lead-lag #2 (x16)
Lead-lag #3 (x17)
Lead-lag #4 (x31)
Logic Limiter Washout Filter
Logic Status Point 1 (S1)
Logic Status Point 2 (S2)
Logic Status Point 3 (S3)
Logic Status Point 4 (S4)
Logic Status Point 5 (S5)
Logic Status Point 6 (S6)
LVRT Desired var Reference
LVRT var Reference
Mechanical power (x10)
Mechanical power (x11)
Mechanical power (x7)
Mechanical power (x8)
Mechanical power (x9)
Negative sequence current (I2)
Negative sequence voltage (V2)
Network Load Share
Null Balance Level (Null Balance)
Null Balance State (Null State)
OEL controller output (OelOutput)
OEL reference
OEL state
Phase A current (Ia)
Phase A to B, line-to-line voltage (Vab)
Phase B current (Ib)
Phase B to C, line-to-line voltage (Vbc)
Phase C current (Ic)
Phase C to A, line-to-line voltage Vca
Position Indication (PositionInd)
Positive sequence current (I1)
Positive sequence voltage (V1)
Post-limit output (Post)
Power factor (PF)
Power HP #1 (x5)
Power Input
Pre-limit output (Prelim)
PSS electrical power (PssW)
PSS terminal voltage (Vtmag)
Reactive power (var)
Real power (W)
SCL controller output (SclOutput)
SCL reference
SCL state
SCL PF reference
Speed HP #1 (x2)
Synthesized speed (Synth)
Terminal frequency deviation (TermF)
Terminal Voltage Low Pass Filter
Terminal Voltage Ramp Limiter
Time response signal (Ptest)
Torsional filter #1 (Tflt1)
Torsional filter #2 (x29)
Total power (VA)
Transfer Output
UEL controller output (UelOutput)
UEL reference
UEL state
Var/PF error
Var/PF state
Var/PF output
Washed out power (WashP)