24-2 9492600990
Testing DECS-150
Graph Parameters
Any four of the following parameters may be selected for plotting in the graph areas.
• APC Error to PI
• APC Integrator state
• APC PI output
• Auxiliary voltage input (Vaux)
• Average line current (Iavg)
• Average line-to-line voltage (Vavg)
• AVR error signal (Errln)
• AVR output
• Bus frequency (B Hz)
• Bus voltage (Vbus)
• Compensated frequency deviation (CompF)
• Control output (CntOp)
• Cross-current input (Iaux)
• Desired APC Reference
• Droop
• FCR error
• FCR state
• FCR output
• Field current (Ifd)
• Field voltage (Vfd)
• Filtered mechanical power (MechP)
• Final PSS output (Pout)
• Frequency response signal (Test)
• Generator/Motor frequency (G/M Hz)
• Grid connect state
• Grid code test signal
• Internal state (TrnOp)
• Lead-lag #1 (x15)
• Lead-lag #2 (x16)
• Lead-lag #3 (x17)
• Lead-lag #4 (x31)
• Logic Limiter Washout Filter
• Logic Status Point 1 (S1)
• Logic Status Point 2 (S2)
• Logic Status Point 3 (S3)
• Logic Status Point 4 (S4)
• Logic Status Point 5 (S5)
• Logic Status Point 6 (S6)
• LVRT Desired var Reference
• LVRT var Reference
• Mechanical power (x10)
• Mechanical power (x11)
• Mechanical power (x7)
• Mechanical power (x8)
• Mechanical power (x9)
• Negative sequence current (I2)
• Negative sequence voltage (V2)
• Network Load Share
• Null Balance Level (Null Balance)
• Null Balance State (Null State)
• OEL controller output (OelOutput)
• OEL reference
• OEL state
• Phase A current (Ia)
• Phase A to B, line-to-line voltage (Vab)
• Phase B current (Ib)
• Phase B to C, line-to-line voltage (Vbc)
• Phase C current (Ic)
• Phase C to A, line-to-line voltage Vca
• Position Indication (PositionInd)
• Positive sequence current (I1)
• Positive sequence voltage (V1)
• Post-limit output (Post)
• Power factor (PF)
• Power HP #1 (x5)
• Power Input
• Pre-limit output (Prelim)
• PSS electrical power (PssW)
• PSS terminal voltage (Vtmag)
• Reactive power (var)
• Real power (W)
• SCL controller output (SclOutput)
• SCL reference
• SCL state
• SCL PF reference
• Speed HP #1 (x2)
• Synthesized speed (Synth)
• Terminal frequency deviation (TermF)
• Terminal Voltage Low Pass Filter
• Terminal Voltage Ramp Limiter
• Time response signal (Ptest)
• Torsional filter #1 (Tflt1)
• Torsional filter #2 (x29)
• Total power (VA)
• Transfer Output
• UEL controller output (UelOutput)
• UEL reference
• UEL state
• Var/PF error
• Var/PF state
• Var/PF output
• Washed out power (WashP)
• Washed out speed (WashW)