38
Operating Manual for BAUER LINESTAR 9000 with hose feed
Wheel gear TNT2
The wheel gear type TNT2 have not got any grease fittings for greasing the bale assembly.
15.3.2 DRIVE MOTOR
Spur gear with 40:1 reduction ratio optional 30:1
Standard output 0.55 kW optional 1.1 kW
Travelling speed with tires 14.9-24 ratio 40:1 = 144 m/h
ratio 30:1 = 193 m/h
Used oil quality: SAE 50W, or SAE 20W-50 multigrade motor oil
Oil quantity approx. 3.8 litres up to bottom edge of filling hole
15.4 OSCILLATOR BOX (ONLY WITH BELOW GROUND GUIDANCE)
If you have purchased a LINESTAR with Below Ground Guidance, be sure that the oscillator box is supplied with
voltage. With a 230V AC supply, put the main switch of power supply to position "1". With a 24V DC battery supply
(2 x 12V DC), check if the batteries are connected and sufficiently loaded.
Ensure that the BELOW GROUND CABLE for linear guidance of the system is properly connected to the oscillator
box, also see here 10.3.1 OSCILLATOR BOX, STEERING ANTENNAS, TRACK UNIT.
Check the correct orientation of the antennas of the below ground guidance relative to the machine and to the
linear guidance, see here 12.3 ALIGNING THE CENTRAL UNIT TO THE LINEAR GUIDANCE (BELOW GROUND
GUIDANCE)
Schmiernippel
Grease fittings
Ausrückhebel
Handle