56
Operating Manual for BAUER LINESTAR 9000 with hose feed
19 TROUBLESHOOTING
FAILURE
POSSIBLE CAUSE
REMEDY
System shut down
automatically:
a) power generating unit
low fuel
battery low
loose terminals
low coolant
low oil pressure
loose V-belt
refuel
recharge
tighten
fill up
soiled oil filter
fill up lube oil
tighten
System running in safety
circuit
doglegging
faulty system alignment
microswitch defective
obstacle in the track
intermediate stop switch has been
actuated
leakage-current relay triggered by short
circuit to system
see Restart after doglegging
correction by trained
service staff
replace microswitch
remove obstacle
adjust stop bracket properly or
remove obstacle
reset leakage-current relay
(blue reset button)
Abnormal motor or gearbox
noise
low oil level
oil worn
defective bearing
add oil
change oil
replace bearing
System does not start up main switch turned off
safety disconnect Q1 turned off
fuses of fuse switch disconnector
defective
fuses F1, F2, F3, F4 defective
safety circuit interrupted because system
flex larger than maximum permissible
bending angle
no water pressure
(only with low-pressure shut-off option)
turn it on
turn it on
replace defective fuses
replace defective fuses
see “Restart after doglegging”
check water supply
readjust pressure switch
A certain tower always runs
inside the safety circuit
Wrong microswitch setting in the
alignment control
microswitch defective
contactor defective
cable loose
tower slips
thermal protection (inside motor) has
responded because of:
obstacle in the track
deep soil
low oil in wheel gear
readjust microswitch
replace microswitch
replace contactor
check connections and tighten
if necessary
level the track
remove obstacle
fill up and level the track
add oil
In forward and backward run
the central unit is keeping a
different distance to the
cable/furrow guidance
The micro switches of the linear control
are adjusted differently
Adjust micro switches in both s