Owner‘s manual
40
Caution
» Never use the gas locker to store other parts or hardware.
» NeverleavecraftunattendedwhenLPGconsumingappliancesareinuse.
» Whenhavingthegassystemonboardthecampercovermaynotbealteredinanyway,espe-
cially not sealed more than it was when delivered.
» Donotchange/alterthegasbox/locker;Neverpuncturethegasboxandleadpipesthrough
into the interior of the boat.
» Neverinstallelectricalappliancesorwiringinthegasbox/locker.
Warning
» DonotobstructaccesstoLPGsystemcomponentsinanyway–alwayskeeptheaccessclear.
Danger
» DonotsmokeoruseopenamewhenreplacingLPGcylinders.
» Fuel-burningopen-ameappliancesconsumecabinoxygenandreleaseproductsofcombus-
tionintothecraft.Ventilationisrequiredwhenappliancesareinuse.
» Opendesignatedventopeningswhileappliancesareinuse.Donotusethestoveorovenfor
spaceheating.Ensurethatthereisadequateventilation,neverobstructventilationopenings.
6.9.2. Ventilation/aeration
The following venting openings must be kept clear and open when operation the gas system and its components.
Pos Typeoftting Position
1 Portlights IntegratedintothelargewindowareainthevicinityoftheGalley,alsointheopposite
side of the boat
2 Companionway Leading from deck to saloon and galley
3 Deck hatches Allpossiblehatchesintheareaofgalleyandsalon