75.5957.01 EAGLE FAMILY 20180508 Page 3 of 4
XXS
0.5 s
XS
1 s
auto
< 10 ft
low
bi
A
S
2 s
open
> 10 ft
normal
uni
P
>
3 s
closed
high
uni
MTF
>
4 s
>
uni
AWAY
>
5 s
>
MTF &
AWAY
>
6 s
>
L
7 s
L
XL
8 s
XL
XXL
9 s
highest
... S, XS, XXS
... L, XL, XXL
+
ZONE SIZE
ZONE SIZE
IMMUNITY FILTER
DETECTION MODE
OUTPUT
CONFIGURATION
bi = two-way detection
uni = one-way detection towards sensor
uni MTF = one-way detection with motion tracking feature
uni AWAY = one-way detection away from sensor
A = active output (NO-contact); relay energizes upon detection
P = passive output (NC-contact); relay de-energizes upon detection
Standard Eagle default = < 10 ft
High-mount Eagle default = > 10 ft
open = the sensor detects constantly. The LED is ON.
closed = the sensor is in standby and does not detect. The LED is OFF.
FACTORY VALUES
Adjust the lateral antenna angle.
When mounting at the maximum height, BEA recommends a 15° tilt angle.
When mounting at the maximum height, BEA recommends the following:
Immunity = low
Zone Size = XXL
Adjust the vertical antenna angle.
OR
RESETTING TO FACTORY VALUES:
ANGLE (standard Eagle)
ANGLE (high-mount Eagle)
HOLD-OPEN TIME
MOUNTING
HEIGHT
DOOR CONTROL
7 ft 7 ft
> 2 sec
MECHANICAL ADJUSTMENTS
SETTINGS (by remote control or push buttons)
Adjust the lateral antenna angle.
10 ft
Adjust the vertical antenna angle.
10 ft