9. ENVIRONMENTAL TEST
Following stability tests in conjunction with FEC standard are carried out (device under test
inoperative):
Dry heat and cold resistance
DIN EN60068- 2-2 Bb / 2-1 Ab
+70°C, 96h / –25°C, 96h
thermal-shock resistance
DIN IEC 60068- 2-14 Na / Nb
-25°C; +70°C / 2 cycles of 3h
Cycles with damp heat (95-100%)
DIN EN 60068– 2-30 Db
+25°C; +55°C / 2 cycles of 12h
Following stability tests are carried out independent of FEC standard:
Dry heat and cold resistance
DIN EN60068- 2-2 Bb / 2-1 Ab