BECKHOFF Drive Technology 4 Product description
AX5000 Version 2.5 25
4.8.4.3 AX5192 and AX5193
Terminal point
Connection
ZK +
Zk +
ZK –
Zk
4.8.5 X0324 V
DC
supply
Terminal
point
Connection
Current consumption
U
p
+
24 V
DC -0/+25%
- periphery
(e.g. separate braking
voltage)
Depending on the connected
consumers (see X06 and
X14, X24)
U
s
+
24 V
DC ±25%
- system supply
60 A-72 A = 3 A
90 A-170 A = 10 A
GND
GND
4.8.6 X04, X05EtherCAT connection
Terminal point
Connection
X04 (IN)
incoming EtherCAT line
X05 (OUT)
outgoing EtherCAT line
4.8.7 X06 Digital I/Os
CAUTION
Destruction of the AX5000!
This connector is not designed for external power supply. It is supplied via
the 24 V supply (U
p
) of connector X03.
Note
Output current
The specified output currents are maximum values. The actual values
depend on your current configuration.