38 WAVE User Manual
DIV
0 ¼ Note
1 ⁄ Note
2 ⁄ Note
3 ⁄ Note
4 ¼ Note Triplet
5 ⁄ Note Triplet
6 ⁄ Note Triplet
Sequencer SysEx Data
Byte Parameter Name Range Notes
0 GAT 0-99
1 DIV 0-6
2 Step-1 / Voice-1 0-127 Seq Data
3 Step-1 / Voice-2 0-127
4 Step-1 / Voice-3 0-127
5 Step-1 / Voice-4 0-127
6 Step-1 / Voice-5 0-127
7 Step-1 / Voice-6 0-127
8 Step-1 / Voice-7 0-127
9 Step-1 / Voice-8 0-127
10 Step-2 / Voice-1 0-127
11 Step-2 / Voice-2 0-127
… … …
513 Step-64 / Voice-8 0-127
514 Step-1 / Attr. Byte 0-127 Attribute Byte for Step-1
…
577 Step-64 / Attr. Byte 0-127 Attribute Byte for Step-64
Wave Specific SysEx
PKT = 0x74 (Wave specic):
SPKT: 0x04 Initiate Calibration
F0 Manu ID Model ID Device ID 0x74 SPKT Calib Type F7
Type: 0=VCA/VCF 1=CV-IN 2=MOD Wheel 3=PITCH Wheel
SPKT: 0x05 Program Preset Sound Parameters Dump Request
F0 Manu ID Model ID Device ID 0x74 SPKT Bank Num Preset Num F7
SPKT: 0x06 Response for Program Preset Sound Parameters Dump Request /
Dump to WAVE Preset Sound Parameters (and store to Preset#):
F0
Manu
ID
Model
ID
Device
ID
0x74 SPKT
Bank
Num
Preset
Num
Version D0 … Dn Checksum F7
D0 …Dn: Preset Value (n = 120)
CheckSum = (u8)(D0+…+Dn)&0x7F
SPKT: 0x07 Edit Buer Sound Parameters Dump Request
F0 Manu ID Model ID Device ID 0x74 SPKT F7
SPKT: 0x08 Response for Edit Buer Sound Parameters Dump Request /
Dump Sound Parameters to WAVE Edit Buer:
F0 Manu ID Model ID Device ID 0x74 SPKT Version D0 … Dn Checksum F7
D0 …Dn: Preset Value (n = 120)
CheckSum = (u8)(D0+…+Dn)&0x7F
SPKT: 0x0A Response for Dump to WAVE Preset Sound Parameters
(and store to Preset#):
F0 Manu ID Model ID Device ID 0x74 SPKT
Bank
Num
Preset
Num
Status F7
Status: 0 = Data Length/Checksum were wrong / 1 = Success
SPKT: 0x0C Response to Dump Sound Parameters to WAVE Edit Buer:
F0 Manu ID Model ID Device ID 0x74 SPKT Status F7
Status: 0 = Data Length/Checksum were wrong / 1 = Success
SPKT: 0x0D Program Sequencer Data Dump Request
F0 Manu ID Model ID Device ID 0x74 SPKT
Bank
Num
Preset
Num
F7
SPKT: 0x0E Response for Program Sequencer Data Dump Request /
Dump to WAVE Sequencer Data (and store to Preset#):
F0
Manu
ID
Model
ID
Device
ID
0x74 SPKT
Bank
Num
Preset
Num
Version D0 … Dn Checksum F7
D0 …Dn: Preset Value (n = 577)
CheckSum = (u8)(D0+…+Dn)&0x7F
SPKT: 0x0F Edit Buer Sequencer Data Dump Request
F0 Manu ID Model ID Device ID 0x74 SPKT F7
SPKT: 0x10 Response for Edit Buer Sequencer Data Dump Request /
Dump Sequencer Data to WAVE Edit Buer:
F0 Manu ID Model ID Device ID 0x74 SPKT Version D0 … Dn Checksum F7
D0 …Dn: Preset Value (n = 577)
CheckSum = (u8)(D0+…+Dn)&0x7F
SPKT: 0x12 Response for Dump to WAVE Sequencer Data (and store to Preset#):
F0 Manu ID Model ID Device ID 0x74 SPKT
Bank
Num
Preset
Num
Status F7
Status: 0 = Data Length/Checksum were wrong / 1 = Success