Installation OCTOPUS OS3
Release
03
08/2020
49
7.4 Signal contact
7.5 Climatic conditions during operation
7.6 Climatic conditions during storage
Signal contact
Connection type 5-pin, “A”-coded M12 plug
Tightening torque 4.5 lb-in (0.51 Nm)
Nominal value I
max
=1A at U
max
= 30 V AC (resistive load)
I
max
=2A at U
max
= 30 V DC (resistive load)
I
max
=1A at U
max
= 60 V DC (resistive load)
Table 25: Signal contact
Climatic conditions during operation
Minimum clearance around the device 4 in (10 cm)
Ambient air temperature
a
a. Temperature of the ambient air at a distance of 2 in (5 cm) from the device
Devices with operating temperature
characteristic value V (standard):
up to 6562 ft ASL (2000 m ASL)
-40 °F ... +140 °F
(-40 °C ... +60 °C)
6560 ft ASL ... 9842 ft ASL
(2000 m ASL ... 3000 m ASL)
-40 °F ... +131 °F
(-40 °C ... +55 °C)
Devices with operating temperature
characteristic value T (extended):
up to 6562 ft ASL (2000 m ASL)
-40 °F ... +158 °F
(-40 °C ... +70 °C)
6560 ft ASL ... 9842 ft ASL
(2000 m ASL ... 3000 m ASL)
-40 °F ... +149 °F
(-40 °C ... +65 °C)
Humidity 5 % ... 100 %
(also in condensing atmospheres)
Air pressure
min. 700 hPa (+9842 ft; +3000 m)
max. 1060 hPa (-1312 ft; -400 m)
Table 26: Climatic conditions during operation
Climatic conditions during storage
Ambient
temperature
-40 °F ... +185 °F (-40 °C ... +85 °C) up to 3 months
-40 °F ... +158 °F (-40 °C ... +70 °C) up to 1 year
-40 °F ... +122 °F (-40 °C ... +50 °C) up to 2 years
+32 °F ... +86 °F (0 °C ... +30 °C) up to 10 years
Humidity 5 % ... 100 % (also in condensing atmospheres)
Air pressure
min. 600 hPa (+13123 ft; +4000 m)
max. 1060 hPa (-1312 ft; -400 m)
Table 27: Climatic conditions during storage