10AP Series Two-Post Lifts 24 P/N 5900265 — Rev. A6 — December 2022
To put the Equalizing Cables into position:
Put both Posts either flat on the ground or elevated on a sawhorse or similar. The
insides
of the
Posts must be accessible, facing up.
Slide the Lift Heads away from the bottom of both Posts. Far enough to provide access to the
bottom of the lift post and the Post Sheave.
Reference only – do not scale.
Retrieve the two Equalizing Cables for your Lift. Each model has a specific Equalizing Cable length
as noted in the table below.
Model Part Number Equalizing Cable
Assembly Dia.
and Length
10AP 5595731 Ø10 x 10,193 mm
10AP-168 5595732 Ø10 x 11,422 mm
10APX 5595733 Ø10 x 10,812 mm
10AP-181 5595734 Ø10 x 12,027 mm
Remove the Post Sheave from the bottom of both Posts.
Illustration shows the Cable Sheave
near the bottom of the Post.
Reference only – do not scale.
NOTICE Keep the Post Sheave, Sheave Pin, and Bolt nearby; you will be re-installing them soon.