33 Bentone
Replacement of cartridge filter Mounting/dismounting return plug
One pipe system
Two pipe system
Unscrew the cartridge filter plug
in the cover by means of a 4 mm
allen key and withdraw the cartridge
filter. If necessary, put a screwdriver
between the cartridge filter and the
plug and turn the cartridge filter
carefully until it comes off. Reject
the cartridge filter and replace it by
a new one. Press it on to the plug.
Ensure that the
O-ring is not damaged. Then fit the
new cartridge filter to the pump.
Removed for single pipe
system
Plug fitted for single pipe
system