165 105 96
7. Instructions Pump
7.1 DANFOSS BFP41
Technical data
Viscosity range:: 1,3-12,0 mm
2
/s
Pressure range:: 7-15 bar
Rated voltage of coil: 220/240V 50/60 Hz
Oil temperature:: max 60°C
Components
1. Nozzle port G1/8”
2. Pressure gauge port
3. Pressure adjustment, 4mm allen key
4. Cartridge filter
5. Vacuum gauge port G1/8”
6. Return line G¼”
7. Suction line G¼”
8. Return plug