35
Bentone B40 MF/B45-2 MF
For installers
S
T
5.6 Replacement of electrical
components
1. Break the main current and disconnect the Euro plugs from the burner.
2. Note the connection of the existing component.
3. Remove the existing component.
4. Install the new component using the same wiring as the existing
component or the specifi ed alternative arrangement.
5. Fit the Euro plugs and turn on the main current.
6. Check the function of the new component.
7. Start the burner. Check combustion. *
5.7 Replacement of preheater
overheating protector
It is usually apparent that the preheater overheating protector needs
replacing when the preheater fi nds it diffi cult to maintain a suffi ciently high
temperature, resulting in problems in retaining stable combustion.
1. Break the main current and disconnect the Euro plugs from the burner.
2. Remove the preheater hood, loosen the screws (K)
3. Measure out which overheating protectors (T) need replacing. (A
broken overheating protector has broken conductivity.)
4. Note the overheating protector connection points.
5. Remove the overheating protector.
6. Install and connect the new overheating protector. During installation,
the overheating protector shall simply be inserted fully into its sensor
tube on the preheater.
7. Fit the preheater hood using the screws (S).
8. Fit the Euro plugs and turn on the main current.
9. Start the burner. Check combustion. *
Note:
* When servicing/replacing components that affect combustion, an
analysis and soot test shall be carried out on the installation.
!
Use caution when
operating the burner,
surfaces may be hot.