Safety equipment
1003090-EI-2.0 Issued 2006-12-21 11
6.1 Standard
6.1.1 Compressible safety switches
Compressible safety switches on the drum edges. These stop the rotation if com-
pressed. When the obstacle is removed, the rotation continues.
6.1.2 Force sensitive door leaves
If the system detects an obstacle blocking the door, the power to the motor is
shut-off
The door makes three attempts to start. After these three attempts the door
waits for a while and then makes one new attempt to start
If the door is pushed out of position during this waiting period, the system is
reset and starts to operate according to preset mode.
When the obstacle is removed the system can also be reset by pressing the
reset push-button