30 Issued 2006-12-21 1003090-EI-2.0
11.3 Code list
For all other error codes call Besam Service.
Code Status Cause Remedy
ON The revolving door is function-
ing normally
10 Stop Check for obstacles between the
wing and the floor and between the
wing and the inside of the drum.
Check trip switches. Close escape
doors
11 Electromechanical lock error No signal from the electro-
mechanical lock
Make one more unlock/lock opera-
tion. If that does not help call
Besam Service
20 Emergency stop Emergency stop push-button
depressed
Release the button by turning it in
the direction of the arrows, then
restore function by striking C on
the PCD
21 Response from the PDR sensor
fitted above the opening on the
inside
Inner PDR sensor activated Remove obstacle in the inner detec-
tion zone. Adjust the inner detec-
tion zone if necessary
22 Response from the PDR sensor
fitted above the opening on the
outside
Outer PDR sensor activated Remove obstacle in the outer detec-
tion zone. Adjust the outer detec-
tion zone if necessary
25 Response from the sensors on
the door leaves
The detection zone of the sensor
activated
Remove obstacle in the detection
zone. Adjust the detection zone if
necessary
26 Response from the sensors on
the door leaves
The detection zone of the sensor
activated
Remove obstacle in the detection
zone. Adjust the detection zone if
necessary
30 Blocked door The wing is blocked by an obsta-
cle
Check for obstacles between the
wing and the floor and between the
wing and the inside of the drum.
After checking press C
32 Power fail input Main power lost Check main fuse.
Check external power supply