EasyManua.ls Logo

Besam RD3 - Read Speed Settings; Real Time Clock; Read Real Time Clock

Default Icon
36 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Programme selector PCD
1003090-EI-2.0 Issued 2006-12-21 19
7.5 Read speed settings
1. Type F3. The display shows S1.
2. Use or to select setpoint number to read.
3. Press C to leave the menu.
7.6 Real time clock
The CDC system has a real time clock built in. The clock is used for the log
record and when the door is running under real time settings.
7.6.1 Read real time clock
1. Type F71. The display shows 11 and present parameter value relating to year.
2. Use or to select parameter number and display the parameter value.
3. Press C to leave the menu.
Summer and wintertime (see “Summertime/Wintertime” on page 18).
Setpoint Description Setpoint value
S1 High speed setpoint 1.0-6.0 rpm
S2 Low (handicap) speed setpoint 0.2-2.5 rpm
S3 Creep speed setpoint Fixed at 0.5 rpm
S4 Continuous speed setpoint 1.0-2.5 rpm
S5 Manual speed setpoint 0.2-2.0 rpm
S9 Door size parameter 1-9
FUNC
DATA
EAA254
↑/↓
11 Year
12 Month
13 Date
14 Hour
15 Minute
16 Second

Table of Contents