- 29 -
Control unit
EN
ENGLISH
8. PROGRAMMING
8.1 BASIC FUNCTIONS
To access programming, press button F for 2 seconds.
Programming is divided into 4 levels.
To go to the next level keep button F pressed and press the + key (Sequence 1-2-3-4-1.......).
After selecting the level wanted, press button F to display the functions available in consecutive order. Each time F is pressed the menu shifts
to the next function (/R - &/ - )W.....)
With the function selected, use the
+
or
-
key to change the value of the parameter (
+
: ---... /
-
: ...---).
The changes made to the parameters are active immediately, but will be permanently saved only when exiting the menu, selecting the ST
function with key F.
NOTE: In case of power failure during programming, all changes will be lost.
F
- +
F
F
2
nd
level
R6W
=bollard closed
F
F
F
F
F
F
F
F
F
F
F
F F+
+
+
+
-
-
-
+
+
+
+
+
+
+
+
x 2”
x 2”
x 5 x 3x 4
1st level
programming
Selects each single
1st level function
(see table par.8.2)
Selects each single
2nd level function
(see table par.8.3)
Selects each single
4th level function
(see table par.8.5)
Changes the values
of each single 1st
level function
(see table par.8.2)
Changes the values
of each single 2nd
level function
(see table par.8.3)
Changes the values
of each single 4th
level function
(see table par.8.5)
“67” function
Exit and save
programming
2nd level
programming
4th level
programming
Selecting Output2 set to closed arm:
A
B
C D
E
Example: